 Bulletin PD-21071 rev. A 12/06
30CTH02SPbF 30CTH02-1PbF
Hyperfast Rectifier
Features
* * * * * Hyperfast Recovery Time Low Forward Voltage Drop Low Leakage Current 175C Operating Junction Temperature Lead-Free ("PbF" suffix)
trr =30ns max. IF(AV) = 30Amp VR = 200V
Description/ Applications International Rectifier's 200V series are the state of the art Hyperfast recovery rectifiers specifically designed with optimized performance of forward voltage drop and hyperfast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers.
Absolute Maximum Ratings Parameters
VRRM IF(AV) IFSM TJ, TSTG Peak Repetitive Reverse Voltage Average Rectified Forward Current @ TC = 159C Per Diode Per Device Non Repetitive Peak Surge Current @ TJ = 25C Operating Junction and Storage Temperatures
Max
200 15 30 200 - 65 to 175
Units
V A
C
Case Styles
30CTH02SPbF
30CTH02-1PbF
Base Common Cathode
2
Base Common Cathode
2
1
Anode
2 Common Cathode
3
1
Anode
Anode
2 Common Cathode
3
Anode
D2PAK www.irf.com
TO-262 1
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
Electrical Characteristics @ TJ = 25C (unless otherwise specified)
Parameters
VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage
Min Typ Max Units Test Conditions
200 V V V A A pF nH IR = 100A IF = 15A, TJ = 25C IF = 15A, TJ = 125C VR = VR Rated TJ = 125C, VR = VR Rated VR = 200V Measured lead to lead 5mm from package body
0.92 1.05 0.78 0.85 5 57 8 10 300 -
IR
Reverse Leakage Current
-
CT LS
Junction Capacitance Series Inductance
-
Dynamic Recovery Characteristics @ TC = 25C (unless otherwise specified)
Parameters
trr Reverse Recovery Time
Min Typ Max Units Test Conditions
26 40 2.8 6.0 37 120 35 30 nC A ns IF = 1A, diF/dt = 50A/s, VR = 30V IF = 1A, diF/dt = 100A/s, VR = 30V TJ = 25C TJ = 125C TJ = 25C TJ = 125C TJ = 25C TJ = 125C IF = 15A diF/dt = 200A/s VR = 160V
IRRM
Peak Recovery Current
-
Qrr
Reverse Recovery Charge
-
Thermal - Mechanical Characteristics
Parameters
TJ TStg RthJC Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Weight Mounting Torque Marking Device Per Diode
Min
- 65 - 65 6.0 5.0
Typ
2.0 0.07 -
Max
175 175 1.1 12 10
Units
C C/W g (oz) Kg-cm lbf.in
2
30CTH02S 30CTH02-1
Case style D Pak Case style TO-262
2
www.irf.com
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
100
( A)
100
Tj = 175C
10 1 0.1 0.01 0.001
150C 125C 100C 75C 50C 25C
Instantaneous Forward Current - I
Tj = 175C Tj = 125C
Reverse Current - I
F
(A)
R
0.0001 0 50 100 150 200
Reverse Voltage - VR (V) Fig. 2 - Typical Values of Reverse Current Vs. Reverse Voltage
10
Tj = 25C
1000
(pF)
T J = 25C
Junction Capacitance - C
T
100
1 0.4
10
0.6 0.8 1 1.2 1.4 1.6
0
50
100
150
200
Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics
Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage
10
(C/W)
thJC
Thermal Impedance Z
1
D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01
Notes:
PDM
t1 t2
0.1
Single Pulse (Thermal Resistance)
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01 0.00001
0.0001 0.001 0.01 0.1 1 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
10
www.irf.com
3
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
180
Allowable Case Temperature (C) Average Power Loss ( Watts )
25 20 15 10 5 0 0 5 10 15 20
(A) F(AV)
170
DC
RMS Limit
160
Square wave (D = 0.50)
150 Rated Vr applied
see note (2)
DC
D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5
140 25
Average Forward Current - I
0
Average Forward Current - IF(AV) (A)
5
10
15
20
25
Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
100
IF = 15 A
1000
IF = 15 A
Qrr ( nC )
V R = 390V T J = 125C T J = 25C
trr ( ns )
100
V R = 390V T J = 125C T J = 25C
10 100
1000
10 100
1000
di F /dt (A/s ) Fig. 7 - Typical Reverse Recovery vs. di F /dt
di F /dt (A/s ) Fig. 8 - Typical Stored Charge vs. di F /dt
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 8); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR
4
www.irf.com
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
Reverse Recovery Circuit
VR = 200V
0.01 L = 70H D.U.T. dif/dt ADJUST
diF /dt
D G IRFP250 S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
IF 0
trr ta tb
4
Q rr
2
I RRM
0.5 I RRM di(rec)M/dt 0.75 I RRM
5
1
diF /dt f
1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
Outline Table
Conform to JEDEC outline D2Pak (SMD-220) Dimensions in millimeters and (inches)
Modified JEDEC outline TO-262 Dimensions in millimeters and (inches)
6
www.irf.com
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
Tape & Reel Information
Dimensions in millimeters and (inches)
Part Marking Information
D2PAK
THIS IS A 30CTH02S LOT CODE 8024 ASSEMBLED ON WW 02, 2000
INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE
PART NUMBER
30CTH02S
DATE CODE YEAR 0 = 2000 WEEK 02 P = LEAD-FREE
TO-262
THIS IS A 30CTH02-1 LOT CODE 8024 ASSEMBLED ON WW 02, 2000
INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE
PART NUMBER
30CTH02-1
DATE CODE YEAR 0 = 2000 WEEK 02 P = LEAD-FREE
www.irf.com
7
30CTH02SPbF, 30CTH02-1PbF
Bulletin PD-21071 rev. A 12/06
Ordering Information Table
Device Code
30
1
C
2
T
3
H
4
02
5
S
6
TRL PbF
7 8
1 2 3 4 5 6 7 6 8
-
Current Rating (30A) C T H S = Common Cathode = TO-220, D2Pak = Hyperfast Rectifier = D2Pak
Voltage Rating (02 = 200V) -1 = TO-262 none = Tube (50 pieces) TRL = Tape & Reel (Left Oriented, for D 2PAk package) TRR = Tape & Reel (Right Oriented, for D2PAk package)
-
none = Standard Production PbF = Lead-Free
Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 12/06
8
www.irf.com


▲Up To Search▲   

 
Price & Availability of 30CTH02STRLPBF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X